Heidenhain ls cnc instuctions

Heidenhain ls 803 instuctions

1. Items Included in Delivery - Standard:
   1.1. Measuring system LS 803, LS 803 D, LS 903 including a 3 m connecting cable.
   1.2. Mounting instructions and certificate of inspection.
   
Optional:
   
   1.3. Additional extension cable, standard length 2 m; longer cables available upon request.
   1.4. Armored output cable.

2. General Information:
   - By adhering to the mounting instructions, the measuring system can be easily installed and set into operation. However, if required, installation at the customer's expense can be carried out by contacting the appropriate Heidenhain supplier or our service engineers.
   - If the equipment becomes defective and cannot be repaired by the customer, we recommend returning the equipment to our factory in Traunreut. Depending on the nature of damage, repairs are carried out either free of charge within the conditions of the guarantee or at the customer's expense.
Do not engage or disengage any connectors while equipment is under power! The transport protection clamps should only be removed during the mounting procedure (see paragraph 4.2.5., page 5).

3. Operating Principle:
   - The scanning head mounting block is connected to the scanning carriage by means of a special coupling. The scanning carriage is guided along the glass scale. The light of the long-life lamp is passed through the light-transmitting zones of the incremental scale and onto the solar cells which have been aligned in accordance with the scanning windows. Relative movement of the scanning head to the scale produces light-dark variations, which are converted into sinusoidal signals by the solar cells. Further processing of these signals is carried out within the HEIDENHAIN-counter electronics.
   - LS 803, LS 803 D, LS 903 are equipped with two absolute reference markings which enable re-establishing the reference datum after operational interruptions. A special design with one reference marking at any position within the measuring length is also available (see "Mounting dimensions").

4. Mounting Instructions:

4.1. Mounting Attitudes:
   - LS 803, LS 803 D, LS 903 is splash waterproof when mounted in the following attitudes, provided that sealing lips are not directly exposed to fluids.

Other attitudes offer only insufficient
protection from contamination and should
therefore be avoided.
4.2.
lnstallatíon
4.2.1.
Prepare mounting surfaces C for scale
unit (fig. 2).
The surfaces must be free from paint.
Paгa11e1 tolerance between mounting surfaces and machine guide: 0.02 mm.
For measuring lengths exceeding 620 mm
a 20 mm wide non-greasy surface D with
a clearance of 0.2 mm to 0.5 mm to the
scale unit should be provided. Surface
D shouid extend over the total height of
the measuring unit, and be located at midpoint between mounting surfaces C. This
surface will be used for final cementing
of the transducer with epoxy resin adhesive (e.g. UHU-P1us).
4.2.2.
Mark posítion of M 4 fixing holes for the
scale unit. Drill, tap (min. 10 mm deep),
deburr and remove swarf (fig. 2).
4.2.3.
Pгepaгe mounting surface E(fig. 3 to 6)
and H(fig: 7) for scanning head. The surfaces must be free from paint.
Parallel tolerance between mounting surface E and H for scanning head to machíne guide: 0.1 mm.
Paгallel tolerance of mounting surface E
and right-angle tolerance of mounting
surface H, for scanning head to mounting
surfaces C Іoг scale unít: 0.05 mm.
Distance between mounting surface E for
scanning head and mounting surfaces C
for scale unit: 

4.2.4. Marking Hole Positions:
   - Mark the position of fixing holes (φ 4.5) for mounting possibilities 1b, 2b, 3b, 4b, Va, and Vb, and tapped fixing holes (M4) for mounting possibilities 1a, 2a, 3a, and 4a for the scanning head.
   - Drill, tap, deburr, and remove swarf.
   - Spacing between the two fixing holes:
     - For mounting possibilities 1 to 4: 56 ± 4 mm.
     - Distance between fixing holes of the scanning head and fixing bolts of the scale unit: 25.5 ± 2.5 mm.
     - Alignment of both holes to machine guide: 0.2 mm.
     - For possibility V: 74 ± 0.2 mm.
     - Distance between the two holes and mounting surface for the scale unit:
       - For Va: 3.7 ± 0.2 mm or 2.7 ± 0.2 mm.
       - For Vb: 3.5 ± 0.3 mm or 12.5 ± 0.3 mm.

4.2.5. Remove Transport Protection Clamps:
   - Caution: Do not attempt to turn the scanning head by force, as this can cause damage to the inner coupling.

4.2.6. Lightly Secure Scale Unit:
   - Secure the scale unit with two M4 x 20 DIN 912 screws.

4.2.7. Lightly Secure Scanning Head:
   - Lightly secure the scanning head to mounting surface E or H using M4 screws.

4.2.8. Alignment:
   - Align the scale unit and scanning head so that a clearance of 1 ± 0.3 mm is maintained over the entire measuring range.
   - Surface G' of the scale unit should be parallel to the machine guide within 0.3 mm, and the scanning head should be parallel to the machine guide within 0.1 mm.

4.2.9. Tighten Fixing Screws:
   - Tighten fixing screws for the scale unit and scanning head (torque: 2.5 Nm or 25 cm kg).

4.2.10. For Measuring Lengths Exceeding 620 mm Only:
   - At the mid-point of the transducer between surface D and the scale unit, affix a non-greasy metal foil that is 0.1 to 0.2 mm thinner than the clearance of the cementing gap using epoxy resin adhesive.

4.2.11. For LS 803 Special Design with Flange Socket Only:
   - Secure the flange socket at a suitable location near the scanning head with the two M4 screws (refer to Mounting Dimensions, page 20).
   - Note the maximum length of cable between the scanning head and flange socket: 300 mm.
   - The scanning head and flange socket must be secured to the same machine part.

4.2.12. Check Mounting Tolerances and System Functionality:
   - After completing the installation, carefully check the mounting tolerances to ensure they meet the specified requirements.
   - Verify the functionality of the system by performing a test to ensure all components are working correctly and accurately.

The original leaflets are for sale. A preview is shown. The price of the leaflet is on request.